RAPID PANEL
All Rapid-EPS products are fully tested by Lloyds British test house and have been proven to meet and exceed
the test requirements set out in BS EN 13374:2013 for Class A and Class BCant find what you looking for? Get in touch
RAPID PANEL
With its robust design ensures that the system not only meets but exceeds all global safety standard with unrivalled fixing centres of 2.7m the widest fixing centres on the market today.
The Rapid Panel has been engineered with longevity in mind.
With the Rapid Panel integrated toe-board, we can offer new branding opportunities at no extra cost.
Any RAL colour
Company Logo
Our barriers can meet the test requirement for standard height, extended height and full containment system height.
All products are fully tested by Lloyds British test house and have been proven to meet and exceed the test requirements set out in BS EN 13374 :2013 for Class A and Class B.
Rapid Panel Socks
These socks are designed to slip easy over the panel for the ultimate protection of flying debris.
Work Through Panel
The innovative Rapid Work Through Panel has been designed and tested to meet the requirements laid down in BS EN 13374:2013 for a Class A system.
The simple but efficient patent pending barrier system provides the facility for operatives to safely reach through the panel to access the perimeter of the building without compromising their safety.
As with all Rapid EPS barriers, the Work Through Panel has been designed to meet the challenges and expectations of today’s construction industry.
Rapid Panel Stillages
For added protection all new Rapid panels are shipped in purpose built stackable transportation aids and are shrink wrapped to ensure the product is in pristine condition on arrival.
Robots
Our Rapid Panels are manufactured using the latest robotic technology. Our robotic line alone is capable of manufacturing 3000 Linear Metres of panels per week.
Rapid EPS system testing Class A & Class B
The standard for temporary edge protection system is known as BS EN 13374:2013 and clearly states how the tests should be carried out.
In order to meet requirements for a Class B edge protection system, Class A static load testing should first be carried out.
Class A
The edge protection must resist a horizontal force of 0.3KN whilst maintaining elastic deflection within 55mm. The top guardrail must also accept a vertical force of 1.25KN applied as an accidental loading. The Rapid Edge Protection System has had numerous static loads applied up to four times the requirement.
Class B
Must resist the same static loading requirement’s for Class A and additionally must pass a low dynamic impact sphere. This test applies impact energy of 0.5 KJ to the top rail and 1.1KJ to lower areas.
Wind Loading available on request.